4 Ton Central AC Unit Heat Pump - Top Discharge

Senville

$3,999.99
SKU:
SENTC-48TD-16
UPC:
850083452582
Availability:
Arrives in 2–10 business days after shipment
Adding to cart… The item has been added

Product Overview

Senville · Central Heat Pump System

SENTC-48TD 4 Ton Central Heat Pump

48,000 BTU of ducted, year-round comfort.

Inverter-driven central heating and cooling with a compact top-discharge outdoor unit, quiet indoor operation and R-32 refrigerant.

17.6 SEER2Rated efficiency
48,000 BTUNominal capacity
As low as 44 dBLow indoor setting
R-32Refrigerant

Performance at a Glance

17.6SEER2
9.1HSPF2 Region 4
11.3EER2
1,690 CFMMaximum indoor airflow
R-32Refrigerant
Cutaway view of a home with a compact top-discharge Senville central heat-pump system
Compact outdoor design

Top-Discharge Central Comfort

The indoor air handler distributes conditioned air through central ductwork while the compact top-discharge inverter heat pump provides heating and cooling outdoors.

Why Choose the SENTC-48TD?

Inverter operationVariable-speed inverter technology adjusts system output to help maintain steady indoor temperatures and reduce unnecessary energy use. Ducted heating and coolingThe 4 ton system is intended for larger residential spaces requiring higher-capacity heating and cooling; final sizing must be confirmed from the building load and duct design. Configurable supplemental heatSelect no auxiliary heater or a 5 kW, 10 kW, 15 kW or 20 kW heater above. A qualified HVAC professional should confirm the required capacity and electrical service.
Configured with your system

Choose the Installation Configuration You Need

Senville SENTC-48TD indoor air handler and compact top-discharge outdoor heat pump
Indoor and outdoor unitsSENTC-48TD central system
Selectable Senville 3/4-inch and 3/8-inch central-system line set
Selected installation kit16 ft. or 50 ft.
Senville auxiliary electric heat module for a central air handler
Selected auxiliary heaterNone, 5 kW, 10 kW, 15 kW or 20 kW
Select both options above
Choose an auxiliary-heater option plus either the 16 ft. or 50 ft. installation kit before adding the system to the cart.
50 ft. communication wire not included
Selecting the 50 ft. installation kit does not include a 50 ft. communication wire. The required communication wiring must be supplied separately for installation.
Practical options

Complete Your Central-System Configuration

Senville 5 kW auxiliary heater for a central air handler
SELECTABLE ABOVE · ALSO SOLD SEPARATELY

5 kW auxiliary heater

Optional supplemental electric heat. Have the HVAC contractor confirm the building load and electrical requirements before selection.

View 5 kW heater →
Senville 10 kW auxiliary heater for a central air handler
SELECTABLE ABOVE · ALSO SOLD SEPARATELY

10 kW auxiliary heater

Optional supplemental electric heat. Have the HVAC contractor confirm the building load and electrical requirements before selection.

View 10 kW heater →
Senville 15 kW auxiliary heater for a central air handler
SELECTABLE ABOVE · ALSO SOLD SEPARATELY

15 kW auxiliary heater

Optional supplemental electric heat. Have the HVAC contractor confirm the building load and electrical requirements before selection.

View 15 kW heater →
Senville 20 kW auxiliary heater for a central air handler
SELECTABLE ABOVE · ALSO SOLD SEPARATELY

20 kW auxiliary heater

Optional supplemental electric heat. Have the HVAC contractor confirm the building load and electrical requirements before selection.

View 20 kW heater →

Buy with Confidence

AHRI-rated performance

AHRI reference 218338225
Review the linked AHRI record and EnergyGuide information for the certified system combination.

Compact top-discharge design

The outdoor unit discharges air upward, providing a compact central heat-pump format for installations where side-discharge clearance is less practical.

Professional installation required. A qualified HVAC professional must confirm equipment sizing, ductwork, auxiliary-heat selection, electrical requirements, refrigerant piping and commissioning for the completed installation.
▶▼Technical Specifications+−
Efficiency Ratings
SEER2 17.6 BTU/W
EER2 11.3 BTU/W
HSPF2 (Region 4) 9.1 BTU/W
COP (Heating) 3.39 W/W
Cooling Performance
Rated Cooling Capacity 47,000 BTU/h
Cooling Capacity Range 15,000 – 49,000 BTU/h
Cooling Input Power 4,159 W (range: 830–5,700 W)
Cooling Current Draw 18.8 A (range: 3.7–25.3 A)
Capacity @ 109°F Outdoor 40,000 BTU/h
Capacity @ 5°F Outdoor 48,000 BTU/h
Cooling Operating Range (Outdoor) 5°F – 131°F
Heating Performance
Rated Heating Capacity 50,000 BTU/h
Heating Capacity Range 11,000 – 52,000 BTU/h
Heating Input Power 4,320 W (range: 830–5,700 W)
Capacity @ 47°F Outdoor 50,000 BTU/h
Capacity @ 17°F Outdoor 30,000 BTU/h
Capacity @ 5°F Outdoor 36,000 BTU/h
Capacity @ –4°F Outdoor 32,000 BTU/h
Heating Operating Range (Outdoor) –4°F – 75°F
Electrical
Power Supply 208/230V, 60 Hz, 1-Phase
Indoor MCA / MOP 7 A / 15 A
Outdoor MCA / MOP 36 A / 40 A
Compressor RLA 6.8 A
Outdoor Fan Motor RLA / Output 2.3 A / 200 W
Indoor Fan Motor RLA / Output 5.4 A / 560 W
Communication Wiring AWG 25×3 Shielded
Refrigerant & Piping
Refrigerant Type R-32
Factory Refrigerant Charge 3.4 kg (119.9 oz)
Additional Charge Rate 0.52 oz/ft (48 g/m)
Liquid / Gas Line Size 3/8 in / 3/4 in
Max. Pipe Length 246 ft (75 m)
Max. Height Difference 98.4 ft (30 m)
Connection Method Flared
Throttle Type (Outdoor / Indoor) EXV / Piston
Compressor
Compressor Type Twin-Rotary DC Inverter
Compressor Model / Brand KTQ420D41SN5A1 / GMCC
Airflow & Sound
Indoor Airflow — High / Low 1,690 / 750 CFM
Indoor Noise Level — High / Low 51 / 44 dB(A)
Outdoor Airflow (Max) 3,050 CFM
Outdoor Noise Level 60 dB(A)
Dimensions & Weight
Indoor Unit (W × D × H) 24-31/64" × 21-1/32" × 52-63/64"
Indoor Net / Gross Weight 164 / 181 lbs
Outdoor Unit (W × D × H) 29-9/64" × 29-9/64" × 32-7/8"
Outdoor Net / Gross Weight 187 / 196 lbs

Frequently Asked Questions Before Purchase

▶▼Is the SENTC-48TD a concealed-duct mini split?+−

No. It is a central ducted heat-pump system with an indoor air handler and a compact top-discharge outdoor unit, designed to distribute conditioned air through central ductwork.

▶▼Which auxiliary-heater option should I select?+−

This product can be configured with no auxiliary heater or a 5 kW, 10 kW, 15 kW or 20 kW module. The correct choice depends on the building heat load, climate and electrical capacity and should be confirmed by a qualified HVAC professional.

▶▼Which installation-kit lengths are available?+−

Choose either the 16 ft. or 50 ft. installation kit above. The installer must confirm the required routing, 3/8 in. liquid line, 3/4 in. gas line, allowable length and refrigerant requirements before installation.

▶▼Does the 50 ft. installation kit include 50 ft. of communication wire?+−

No. The 50 ft. kit selection does not include a 50 ft. communication wire. The required communication wiring must be supplied separately for the installation.

▶▼What are the published operating-temperature ranges?+−

The supplied specifications list outdoor cooling operation from 5°F to 131°F and outdoor heating operation from -4°F to 75°F.