3 Ton Central AC Unit Heat Pump - Top Discharge

Senville

$3,499.99
SKU:
SENTC-36TD-16
UPC:
850083452872
Availability:
Arrives in 2–10 business days after shipment
Adding to cart… The item has been added

Product Overview

Senville · Central Heat Pump System

SENTC-36TD 3 Ton Central Heat Pump

36,000 BTU of ducted, year-round comfort.

Inverter-driven central heating and cooling with a compact top-discharge outdoor unit, quiet indoor operation and R-32 refrigerant.

18.6 SEER2Rated efficiency
36,000 BTUNominal capacity
As low as 38 dBLow indoor setting
R-32Refrigerant

Performance at a Glance

18.6SEER2
9.0HSPF2 Region 4
11.7EER2
1,110 CFMMaximum indoor airflow
R-32Refrigerant
Cutaway view of a home with a compact top-discharge Senville central heat-pump system
Compact outdoor design

Top-Discharge Central Comfort

The indoor air handler distributes conditioned air through central ductwork while the compact top-discharge inverter heat pump provides heating and cooling outdoors.

Why Choose the SENTC-36TD?

Inverter operationVariable-speed inverter technology adjusts system output to help maintain steady indoor temperatures and reduce unnecessary energy use. Ducted heating and coolingThe 3 ton system is intended for medium-sized homes requiring balanced heating and cooling; final sizing must be confirmed from the building load and duct design. Compact top-discharge formatThe compact outdoor unit discharges air upward, making the system suitable for tighter installation areas when all manufacturer clearances are maintained.
Configured with your system

Choose the Installation-Kit Length You Need

Senville SENTC-36TD indoor air handler and compact top-discharge outdoor heat pump
Indoor and outdoor unitsSENTC-36TD central system
Selectable Senville 3/4-inch and 3/8-inch central-system line set
Selected installation kit16 ft. or 50 ft.
Select the required length above
Choose either the 16 ft. or 50 ft. installation kit before adding the system to the cart. The installer must confirm routing, allowable length and refrigerant requirements.
50 ft. communication wire not included
Selecting the 50 ft. installation kit does not include a 50 ft. communication wire. The required communication wiring must be supplied separately for installation.
Practical options

Plan Your Installation

Senville 16 ft. insulated 3/4-inch and 3/8-inch central-system line set
SELECTABLE ABOVE · ALSO SOLD SEPARATELY

16 ft. installation kit

The shorter selectable line-set option for installations where the approved equipment placement permits this routing.

View 16 ft. line set →
Senville 50 ft. insulated 3/4-inch and 3/8-inch central-system line set
SELECTABLE ABOVE · ALSO SOLD SEPARATELY

50 ft. installation kit

A longer selectable line-set option. The 50 ft. communication wire is not included and must be supplied separately.

View 50 ft. line set →
Installed central heat-pump system serving a home through ductwork
REQUIRED · LABOR SOLD SEPARATELY

Professional installation

A qualified HVAC professional must confirm sizing, ductwork, electrical requirements, piping and final commissioning.

Find an installer →

Buy with Confidence

AHRI-rated performance

AHRI reference 218338224
Review the linked AHRI record and EnergyGuide information for the certified system combination.

Compact top-discharge design

The outdoor unit discharges air upward, providing a compact central heat-pump format for installations where side-discharge clearance is less practical.

Professional installation required. A qualified HVAC professional must confirm equipment sizing, ductwork, electrical requirements, refrigerant piping and commissioning for the completed installation.
▶▼Technical Specifications+−
Efficiency Ratings
SEER2 18.6 BTU/W
EER2 11.7 BTU/W
HSPF2 (Region 4) 9.0 BTU/W
COP (Heating) 3.20 W/W
Cooling Performance
Rated Cooling Capacity 34,000 BTU/h
Cooling Capacity Range 13,000 – 38,000 BTU/h
Cooling Input Power 2,906 W (range: 460–3,600 W)
Cooling Current Draw 13.2 A (range: 2.1–16 A)
Capacity @ 109°F Outdoor 32,000 BTU/h
Capacity @ 5°F Outdoor 34,000 BTU/h
Cooling Operating Range (Outdoor) 5°F – 131°F
Heating Performance
Rated Heating Capacity 36,000 BTU/h
Heating Capacity Range 11,000 – 39,000 BTU/h
Heating Input Power 3,300 W (range: 600–3,600 W)
Capacity @ 47°F Outdoor 36,000 BTU/h
Capacity @ 17°F Outdoor 17,500 BTU/h
Capacity @ 5°F Outdoor 27,000 BTU/h
Capacity @ –4°F Outdoor 25,000 BTU/h
Heating Operating Range (Outdoor) –4°F – 75°F
Electrical
Power Supply 208/230V, 60 Hz, 1-Phase
Indoor MCA / MOP 5 A / 15 A
Outdoor MCA / MOP 24 A / 30 A
Compressor RLA 9.45 A
Outdoor Fan Motor RLA / Output 2.3 A / 200 W
Indoor Fan Motor RLA / Output 3.6 A / 375 W
Communication Wiring AWG 25×3 Shielded
Refrigerant & Piping
Refrigerant Type R-32
Factory Refrigerant Charge 2.9 kg (102.3 oz)
Additional Charge Rate 0.52 oz/ft (48 g/m)
Liquid / Gas Line Size 3/8 in / 3/4 in
Max. Pipe Length 246 ft (75 m)
Max. Height Difference 98.4 ft (30 m)
Connection Method Flared
Throttle Type (Outdoor / Indoor) EXV / Piston
Compressor
Compressor Type Twin-Rotary DC Inverter
Compressor Model / Brand KTM240D57UMT / GMCC
Airflow & Sound
Indoor Airflow — High / Low 1,110 / 520 CFM
Indoor Noise Level — High / Low 50 / 38 dB(A)
Outdoor Airflow (Max) 2,800 CFM
Outdoor Noise Level 58 dB(A)
Dimensions & Weight
Indoor Unit (W × D × H) 21-1/32" × 21-1/32" × 49-7/32"
Indoor Net / Gross Weight 137 / 151 lbs
Outdoor Unit (W × D × H) 29-9/64" × 29-9/64" × 25"
Outdoor Net / Gross Weight 143 / 151 lbs

Frequently Asked Questions Before Purchase

▶▼Is the SENTC-36TD a concealed-duct mini split?+−

No. It is a central ducted heat-pump system with an indoor air handler and a compact top-discharge outdoor unit, designed to distribute conditioned air through central ductwork.

▶▼Is this system suitable for my home?+−

The product page describes this 3 ton system for medium-sized homes. Final selection must be based on a professional load calculation, the duct design, insulation, climate and other building conditions.

▶▼Which installation-kit lengths are available?+−

Choose either the 16 ft. or 50 ft. installation kit above. The installer must confirm the required routing, 3/8 in. liquid line, 3/4 in. gas line, allowable length and refrigerant requirements before installation.

▶▼Does the 50 ft. installation kit include 50 ft. of communication wire?+−

No. The 50 ft. kit selection does not include a 50 ft. communication wire. The required communication wiring must be supplied separately for the installation.

▶▼What are the published operating-temperature ranges?+−

The supplied specifications list outdoor cooling operation from 5°F to 131°F and outdoor heating operation from -4°F to 75°F.